NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5920-01-035-1249 Item Description: Arrester Electrical | 5920 | 010351249 | 0 | Y | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A2 | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Tg87 | 5 | 2 | 5 | A2 | DDBJY |
MRC | Criteria | Characteristic |
---|---|---|
ELECTRICAL SURGE | ABHP | OVERALL LENGTH0 188 INCHES NOMINAL |
ELECTRICAL SURGE | ADAV | OVERALL DIAMETER0 075 INCHES MINIMUM AND 0 141 INCHES MAXIMUM |
ELECTRICAL SURGE | ALBY | USAGE DESIGNINDOOR |
ELECTRICAL SURGE | AQAP | ARRESTER TYPEAIR GAP |
ELECTRICAL SURGE | AQAQ | BREAKDOWN VOLTAGE720 000 VOLTS MINIMUM AND 800 000 VOLTS MAXIMUM |
ELECTRICAL SURGE | CQRG | BODY MATERIALGLASS |
ELECTRICAL SURGE | FEAT | SPECIAL FEATURESSHALL BE STABILIZED WITH A RADIOACTIVE ISOTOPE NOT TO EXCEED 1 0 MICROCURIE |