MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/THD BUSHING MTG, TERMINALS ON OPPOSITE END |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAZK | WIDTH ACROSS FLATS | 0.375 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.437 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.875 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | FEEDTHROUGH |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 1000.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -20.00/+20.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWPN | POWER FACTOR AT REFERENCE TEMP IN PERCENT | 1.5000 |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
CQBQ | CAPACITANCE VALUE PER SECTION | 1000.000 PICOFARADS SINGLE SECTION |
CQJX | NOMINAL THREAD SIZE | 0.312 INCHES |