MRC | Criteria | Characteristic |
---|---|---|
FEAT | SPECIAL FEATURES | ELECTRICAL CONNECTION: MATE W/PT06CP-18-325 CONNECTOR;RELIABILITY: MIN.MTBF OF 1,500 HRS WHERE VALUE IS THE SUM OF RANDOM FAILURES OF ALL UNITS IN THE MEASUREMENT SAMPLE DIVIDED BY THE SUM OF ALL OPERATING HRS ON THOSE UNITS |
FTLD | III FUNCTIONAL DESCRIPTION | PROVIDES OUTPUTS TO FLAP SYSTEM, WHICH CORRESPONDS TO SPECIFIC AOA; CONNECTED IN PARALLEL W/EITHER THE CPU-118 OR THE 18-64902 CADC OR THE 14-64912AOA INDICATOR & SHALL BE DRIVEN BY A SYNCRO IN THE AOA TRANSMITTER |
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | C/O 3 SWITCHS;PROVIDES 26VAC POWER TO 1 SYNCRO IN THE AOA TRANSMITTER;AOA SWITCHING ASSY SHALL HAVE MINIMUM RESPONSE OF 0.05 SEC.;DESIGNED TO OPERATE OVRE A VOLTAGE RANGE OF 22.0 TO 30.0 VOLTS AC W/FREQ. VARYING BETWEEN 320.0 TO 480.0HZ,SHALL PERFORM W/O DEGRADATION WHEN THE FREQ. INCREASES TO 515.0HZ OR DECREASE TO 310.0HZ FOR A PERIOD OF 1 SEC.(THESE FREQ. OCCUR APPROX. 12 TIMES PER OPERATING HR ON THE AVE.);LIFE EXPECTANCY: MIN. USEFUL LIFE OF 5000 OPERATING HRS (BASED ON MISSION OF 1 HR W/40 MISSIONS PER MONTH,NO SCHEDULED OVERHAUL,REPLACEMENT OR PARTS ORMAINTAINANCE ADJUSTMENT SHALL BE REQUIRED PRIOR TO COMPLETION OF THE SPECIFIED OPERATING LIFE;STORAGE LIFE: NOT LESS THAN 5 YRS(UNPACKED BEFORE INSTALLATION) |
AGAV | III END ITEM IDENTIFICATION | F-5 |